Rtam Systems Get in touch

Rtam Flow

An eQMS for
medical device
makers.

Rtam flow is a cloud-based electronic Quality Management System for Medical Device Organisations. The Workflow guides all the activities interlinking the relevant clauses with review and approvals for evidence based records.

Explore the modules
The Rtam Flow mark, a continuous wireframe knot in amber, magenta and violet.

Active devices

Pacemakers, infusion pumps

Non-active devices

Surgical instruments, implants

In vitro diagnostics

Test kits, diagnostic assays

Medical device software

SaMD, diagnostic applications

Explore the modules

Nine standard modules cover day-to-day quality work. Seven role-based modules support specialist teams.

Rtam Flow

Standard module

Document management

Keep procedures, work instructions and forms under version control. Reviewers can trace an approved revision back to its changes and approvals.

Standard module

Corrective and preventive action (CAPA)

Investigate the root cause of a quality issue, assign corrective or preventive actions and record the effectiveness check before closure.

Standard module

Audit management

Plan internal and external audits, capture findings and follow each finding through the action and evidence that close it.

Standard module

Competency and training

Define the skills a role requires, schedule training and keep evidence of competence alongside the procedures a person uses.

Standard module

Complaint management

Record a reported device issue, assign its investigation and connect the outcome to corrective action when follow-up is needed.

Standard module

Management review

Bring audit findings, complaints and quality trends into a management review. Record the decisions, action owners and follow-up work.

Standard module

Infrastructure management

Maintain records for the facilities and equipment used in production. Define maintenance plans and retain evidence of completed work.

Standard module

Data analysis

Review quality data across audits, complaints and corrective actions. Use the trends to decide what needs investigation or management attention.

Standard module

Equipment calibration

Control monitoring and measurement equipment through calibration schedules, results and records of instrument status.

Role-based module

Design and development

Trace a medical device from concept through design changes, reviews and approvals to its transfer into production.

Role-based module

Risk management

Identify device hazards, evaluate risks and document the controls and verification evidence throughout the product lifecycle.

Role-based module

Supplier and outsourcing management

Document supplier qualification, monitor performance and keep quality oversight of the processes entrusted to external partners.

Role-based module

Medical device vigilance

Collect and review reports from devices in use. Link findings to post-market surveillance, reporting and clinical follow-up activities.

Role-based module

Marketing and sales

Capture market feedback and route promotional materials for review so teams can trace the claims approved for each market.

Role-based module

Manufacturing

Connect production records to quality checks and deviations. Track how each issue was handled within the manufacturing process.

Role-based module

Regulatory submissions

Organise the documents and evidence required for a target market. Coordinate the reviews that bring a device submission together.

Standards & regulations

From a clause to its evidence.

Rtam Flow connects the requirements that apply to your device with the procedures your team follows and the records that show what happened.

A complaint, traced to closure
  1. ClauseISO 13485, §8.2.2
  2. ProcedureComplaint handling
  3. RecordInvestigation findings
  4. ApprovalClosure sign-off
Quality & risk managementISO 13485 · ISO 14971

ISO 13485:2016 and its European adoption for medical device quality systems. ISO 14971:2019 for identifying, evaluating and controlling device risks.

Software & usabilityIEC 62304 · IEC 62366-1

IEC 62304 for medical device software life-cycle processes and IEC 62366-1 for usability engineering. Link design decisions to development and verification records.

Market and Regulatory SubmissionsEU MDR, IVDR; India MDR, US FDA

Create and Organise records for submission for EU MDR 2017/745, EU IVDR 2017/746, Indian MDR Test and Manufacturing Licenses, US FDA 510k and other country submissions.

Audits & post-market follow-upMDSAP · Post-market surveillance

Prepare evidence for MDSAP audits. Connect complaints, vigilance investigations and corrective actions to post-market surveillance and clinical follow-up records.

How a medical device eQMS works

Why Rtam Flow

Pre-launch estimates based on industry benchmarks and planned product capabilities.

  • Upto 50%

    Less time preparing for audits

  • Upto 30%

    Less rework

  • Upto 60%

    Faster market entry

  • Upto 90%

    Improvement across QMS functions

  • Upto 40%

    Lower cost of quality

The team behind Rtam Flow

Rtam Flow draws on experience in medical device design, manufacturing and the quality systems that connect them.

  • Sriram SL

    Sriram SL

    CEO & Co-Founder

    Sriram brings 45 years in medical devices, including three decades at GE Healthcare and BPL Medical Technologies. He has advised more than 20 companies on their quality systems.

  • Kannan S

    Kannan S

    CFO & Co-Founder

    Kannan founded Madras Cupprum Metals. His 45 years in business span finance, manufacturing operations, sales and quality.

  • Ragav Kannan

    Ragav Kannan

    Head of Marketing

    A co-founder of Paepoi, Ragav has spent more than a decade in marketing and operations, with experience at Caterpillar, Apple and Lam Research.

  • Prashanth Koundinya

    Prashanth Koundinya

    Head of Product & Technology

    Prashanth has worked in medical device engineering for over 12 years, from optical design and verification to ISO 13485 implementation and regulatory submissions.

Talk to Rtam

Ask about a device, a quality workflow or a walkthrough of Rtam Flow.

+919739895559Primary +919940087826Alternate sriram@rtamsystems.com
FFC Jayakamalam, Thiruvanmiyur
Chennai 600041, India